Atmosphere Generators
|
Configuration
The Thermal Dynamix dissociator uses a vertical retort configuration and is available in either electrically heated or, for units of 6,000 scfh or larger capacity, heated by natural gas.
Thermal Dynamix dissociators of 4,000 scfh or less capacity are air cooled. Those of greater than 4,000 scfh may also employ water cooling if the need exists for lower gas output temperature. Thermal Dynamix ammonia dissociators are usually configured to run with an internal system pressure of about 5 psi. We can build high pressure systems with retorts designed to operate up to 20 psi but discourage high pressure systems unless there is no alternative. The reason being that the dissociation process seems to degrade under elevated pressure and the residual ammonia levels in a high pressure system are often greater than those in a low pressure system.
|
|
|